The Time Delay Relay

A Time Delay Relay, connected between the Ignition Switch Relay and the Power Relay should be used on all Hydrogen Fuel Cell Generator Systems; See the Block Diagram.

WHY?
In the event a vehicle Battery becomes Old, used in too Hot, or too Cold a Climate, efficiency becomes considerably less; With a Fuel Cell System immediately drawing current at such time as the Ignition Switch is turned ON, this may be the first problem encountered when attempting to start the Engine.

A Time Delay Relay, set for approximately 30 to 60 seconds will prevent the Fuel Cell from drawing current for the 2 minute time limit, this in turn leaves the vehicle Battery in its normal mode until the Time Delay Relay applies +12 VDC to the Power Relay; Power Relay in turn couples the Vehicle Battery to the actual Fuel Cell Generator along with the associated Oxygen Sensor Equalizer Unit.

NOTE: A 30 second time delay is the factory standard setting. At time of order, if necessary, specify the time delay setting which best fits your particular routine, if any question ?

Tel: Factory @ 1 (928) 472-9200 in Payson, Arizona, or click on the E-Mail link below.

Time Delay Relay - Model # 2906-1
Mechanical and Electrical Specifications:

1.
Time Delay Capability: Adjustable, 30 to 60 seconds
2.
Temperature Capability: -30 to +150 deg. C
3.
Size:
Slim line, Rectangular, with VELCRO adhesive for easy attachment to vehicle interior or in the engine compartment area. 2/1/2 in. Width, 4 1/2 in. Length x 2 in. Depth
4.
Color: Dark Gray, Polyethylene
5.
Switch: For Manual OFF, and Automatic ON, Capability
6.
Weight: Approximately 12 ounces
7.
Voltage +10 to +15 vdc. with primary 5 Amp fuse
8.
Current: 90 ma. Primary consumption, + or -10 ma.

General Purpose of:

1.
Vehicle Operator does not need to make any last minute adjustments, PRIOR TOor AFTER driving a vehicle with the Hydrogen Fuel Cell System, in its standard function.
2.
Reduces strain on Vehicle Battery until after the Engine has been started and running normal. (preferably, with a Time Delay Setting of 30 to 45 seconds).
3.

Time Delay function provides automatic ON and OFF control of either or both, the Fuel Cell Generator and the Oxygen Sensors, Bridging Equalizer Units.

E-Mail Us

Money Order or Personal Check accepted.
No Credit Cards accepted at this time

T
hey only increase cost in behalf of the Banking System

Check to be made payable to:

Koenick Electronics Int'l.
301 N. Whitetail
Payson, Arizona 85541